
Real data and artificial intelligence thinking together to find your part.
In Stock, Ships today
In Stock, Ships today
In Stock, Ships today
In Stock, Ships today
In Stock, Ships today
In Stock, Ships today
Out of stock, but not out of mind! Place your order now and we'll get it to you ASAP.
Out of stock, but not out of mind! Place your order now and we'll get it to you ASAP.
Out of stock, but not out of mind! Place your order now and we'll get it to you ASAP.
Out of stock, but not out of mind! Place your order now and we'll get it to you ASAP.
Out of stock, but not out of mind! Place your order now and we'll get it to you ASAP.
Out of stock, but not out of mind! Place your order now and we'll get it to you ASAP.
Out of stock, but not out of mind! Place your order now and we'll get it to you ASAP.
Out of stock, but not out of mind! Place your order now and we'll get it to you ASAP.
Out of stock, but not out of mind! Place your order now and we'll get it to you ASAP.
Out of stock, but not out of mind! Place your order now and we'll get it to you ASAP.
Out of stock, but not out of mind! Place your order now and we'll get it to you ASAP.
Out of stock, but not out of mind! Place your order now and we'll get it to you ASAP.
Out of stock, but not out of mind! Place your order now and we'll get it to you ASAP.
Out of stock, but not out of mind! Place your order now and we'll get it to you ASAP.
Out of stock, but not out of mind! Place your order now and we'll get it to you ASAP.
Out of stock, but not out of mind! Place your order now and we'll get it to you ASAP.
Out of stock, but not out of mind! Place your order now and we'll get it to you ASAP.
Out of stock, but not out of mind! Place your order now and we'll get it to you ASAP.
Model #: GEHE02411H02B0LLF01010051000000000A
Specs Decoded From The Model Number
Unit Configuration
Standard Efficiency Horizontal 0.5 to 15 Tons
Development Sequence
R-410A
Nominal Capacity
2 Tons
Voltage
208/60/1
Heat Exchanger
Copper-Water Coil
Current Design Sequence
H
Refrigeration Circuit
Heating and Cooling Circuit
Blower Configuration
High Static Blower Motor
Freeze Protection
35°F Freezestat (For Water loop)
Open Digit
0
Supply-Air Arrangement
Left Supply-Air Arrangement
Return-Air Arrangement
Left Return-Air Arrangement
Control Types
UC400
Tstat/Sensor Location
Wall Mounted Location
Fault Sensors
Condensate Overflow Sensor
Temperature Sensor
No Temperature Sensor
Insulation
Standard Fiberglass Insulation
Electric Heat
No Electric Heat
ON/OFF Switch
No "ON"/"OFF" Switch
Filter Type
2" MERV 13
Acoustic Arrangement
Deluxe Sound Attenuation
Unit Drain Pan Option
Polymer Drain Pan