Master-Bilt Ice Cream Dipping Cabinet Troubleshooting
Are your frozen treats melting due to a temperature or power issue? Instead of throwing out the whole unit with that ruined product, try fixing it. Sometimes the problem causing your refrigeration equipment to stop working has an easier fix than you may realize. So try some of these Master-Bilt ice cream dipping cabinet troubleshooting tips before you make that service call.
These troubleshooting tips apply to a variety of Master-Bilt ice cream dipping cabinet models, including DD-26, DC-10D, DC-2S and DD-88 units.
Not Working or Freezing
- Unit isn’t plugged in - Plug in the power cord.
- The condenser coil is dirty - Clean the condenser.
- Circuit breaker is off or tripped - Turn on or reset the breaker.
- Gasket is dirty or damaged - Clean or replace the gasket.
- Temperature isn’t set properly - Adjust the temperature based on the manual recommendations.
- Ambient temperature is too high - Be sure the ambient temperature isn’t too high and that refrigeration equipment is kept away from hot side units such as ovens and fryers.